Position the intake hood
Bring the flexible capture arm close to the soldering point, repair area or nail filing point. Round and rectangular hoods support different bench arrangements.

DESKTOP FUME EXTRACTION
Capture at the source.
Route residual odors outdoors.
MN01W combines a 105W brushless motor, adjustable source capture and three-stage filtration with a side exhaust connection. Use the hood at a soldering or nail workstation, and connect the 2 m exhaust hose when your setup calls for routing residual odors outdoors.
Specifications shown are for the documented 110V version. Confirm voltage and application suitability before ordering.
PRODUCT OVERVIEW
Connect the included 2 m exhaust hose to the left-side metal flange when outdoor venting is needed.
Pre-filter cotton, HEPA filter and odor / activated-carbon filter.
Front-panel operation and remote control.
MODEL INFORMATION
Confirm your material and operating conditions before choosing an extraction system.
| Model | NLVYPRO MN01W |
|---|---|
| Power supply | 110V AC |
| Rated power | 105W |
| Manufacturer-stated airflow | 155 CFM |
| Outdoor exhaust hose | 2 m long / 76 mm diameter |
| Airflow display | S10–S100 |
| Body dimensions | 10.8 × 8.5 × 12.2 inches |
| Control | Front panel and remote control |
| Manufacturer | Dongguan Nenglang Environmental Technology Co., Ltd. |
Airflow is a manufacturer-stated value. Actual capture performance varies with the setting, hose and hood configuration, and filter condition.
MN01W / EXHAUST CONFIGURATION
The side exhaust flange is the key distinction from MN01. Arrange source capture and the exhaust route around your workstation.



TWO SETUP OPTIONS
Bring the flexible capture arm close to the soldering point, repair area or nail filing point. Round and rectangular hoods support different bench arrangements.
Air passes through the pre-filter, HEPA particle filter and activated-carbon layer. Outdoor exhaust is optional for normal soldering setups; assess ventilation for your process.
Attach the exhaust hose to the left-side metal flange to route residual odors outdoors. Keep the discharge away from occupied areas and air intakes, and confirm a suitable outlet for your installation.
The capture hose and outdoor exhaust hose serve different purposes. Additional bends, duct length and filter loading affect airflow. Confirm the installation before ordering.
THREE SEPARATE FILTER LAYERS
The first-stage pad collects larger particles. Inspect it frequently, especially for nail dust and other particle-heavy tasks. The listed package includes 10 spare pre-filter pads.
The second-stage filter captures finer particles. Check filter loading and replace with a compatible MN01W filter as needed.
Carbon helps adsorb odors and certain gaseous contaminants. Its suitability and life depend on the substances present and operating conditions.
Each layer can be replaced separately. Start by checking the first-stage pad when airflow drops or the alarm sounds. Filter life depends on the material, operating time and loading. Odor reduction does not establish that air is safe.
WORKSTATION APPLICATIONS
Use source capture for PCB soldering and electronics repair. Position the hood near the smoke source while keeping room for hands and tools.
Place the hood near the filing area to collect dust as it is generated. Inspect the pre-filter regularly and arrange the hose around your workstation.
MN01W also supports small laser engraving and cutting machines, such as 5W units. Share your material, enclosure and smoke load so we can confirm the capture and outdoor exhaust arrangement.
MN01W shares the soldering, electronics repair and nail-dust applications of MN01, with an additional option for small laser engraving and cutting. A 5W rating alone does not determine suitability: the material, smoke load and connections also matter. Larger machines or heavier smoke loads may require a larger extraction system.
CONTROLS & DAILY CARE
The digital display shows ten airflow levels. Select the setting using the front-panel buttons or remote control.
Switch the unit on or off and adjust suction with the remote when the machine sits beside the bench.
A beeping alert indicates saturated or clogged filters. Switch off and unplug before inspection, starting with the pre-filter. Replace loaded layers according to the manual.
PRODUCT DEMONSTRATION
SELECTION & SUPPORT
MN01W adds a side exhaust connection for the outdoor exhaust hose. Choose it when your installation calls for routing residual odors outdoors. Compare the exact configuration and connections before ordering.
The listed configuration can be used without the outdoor exhaust hose for normal soldering setups. The hose provides an additional routing option; assess material and ventilation requirements for each task.
The Amazon description lists a 2 m outdoor exhaust hose, a flexible capture hose, round and rectangular hoods, remote control and 10 spare first-layer pre-filters. Confirm the final package, voltage and configuration in the selected offer or quotation.
No. The three layers are separately replaceable. Inspect the first-stage pad first, then assess the HEPA and activated-carbon layers according to their condition and the manual.
Contact the factory with your target market, branding requirements and expected quantity. We will confirm the MN01W specification, customization options, warranty terms and quotation.
CHECK YOUR APPLICATION
Tell us your process, material and required quantity.