FUME EXTRACTION EQUIPMENT MANUFACTURERDongguan, China NLVYPRO
MN01W desktop fume extractor with upright flexible extraction arm

DESKTOP FUME EXTRACTION

MN01WDesktop Fume Extractor

Capture at the source.
Route residual odors outdoors.

MN01W combines a 105W brushless motor, adjustable source capture and three-stage filtration with a side exhaust connection. Use the hood at a soldering or nail workstation, and connect the 2 m exhaust hose when your setup calls for routing residual odors outdoors.

Power supply110V AC
Rated power105W
Filtration3 stages
Ask About MN01W ↗Buy on Amazon ↗Download MN01 / MN01W Manual (PDF) ↓

Specifications shown are for the documented 110V version. Confirm voltage and application suitability before ordering.

PRODUCT OVERVIEW

Built around the workbench.

01

Optional outdoor exhaust

Connect the included 2 m exhaust hose to the left-side metal flange when outdoor venting is needed.

02

Three-stage filtration

Pre-filter cotton, HEPA filter and odor / activated-carbon filter.

03

Accessible controls

Front-panel operation and remote control.

MODEL INFORMATION

Technical details.

Confirm your material and operating conditions before choosing an extraction system.

ModelNLVYPRO MN01W
Power supply110V AC
Rated power105W
Manufacturer-stated airflow155 CFM
Outdoor exhaust hose2 m long / 76 mm diameter
Airflow displayS10–S100
Body dimensions10.8 × 8.5 × 12.2 inches
ControlFront panel and remote control
ManufacturerDongguan Nenglang Environmental Technology Co., Ltd.

Airflow is a manufacturer-stated value. Actual capture performance varies with the setting, hose and hood configuration, and filter condition.

MN01W / EXHAUST CONFIGURATION

A closer look at the connections.

The side exhaust flange is the key distinction from MN01. Arrange source capture and the exhaust route around your workstation.

TWO SETUP OPTIONS

Capture first.
Plan the exhaust route.

01 / SOURCE

Position the intake hood

Bring the flexible capture arm close to the soldering point, repair area or nail filing point. Round and rectangular hoods support different bench arrangements.

02 / FILTRATION

Use the internal filter system

Air passes through the pre-filter, HEPA particle filter and activated-carbon layer. Outdoor exhaust is optional for normal soldering setups; assess ventilation for your process.

03 / OPTIONAL EXHAUST

Connect the 2 m hose

Attach the exhaust hose to the left-side metal flange to route residual odors outdoors. Keep the discharge away from occupied areas and air intakes, and confirm a suitable outlet for your installation.

The capture hose and outdoor exhaust hose serve different purposes. Additional bends, duct length and filter loading affect airflow. Confirm the installation before ordering.

MN01 & MN01W / SHARED CONSUMABLES

Three layers. Individually replaceable.

MN01 and MN01W use the same compatible filter set. Identify each layer below when ordering replacements.

Replace loaded layers individually. Switch off and unplug before filter access, and follow the installation order and airflow direction in the manual.

THREE SEPARATE FILTER LAYERS

Replace the layer that needs attention.

01 / PRE-FILTER

Larger particles

The first-stage pad collects larger particles. Inspect it frequently, especially for nail dust and other particle-heavy tasks. The listed package includes 10 spare pre-filter pads.

02 / HEPA

Fine particles

The second-stage filter captures finer particles. Check filter loading and replace with a compatible MN01W filter as needed.

03 / ACTIVATED CARBON

Odor adsorption

Carbon helps adsorb odors and certain gaseous contaminants. Its suitability and life depend on the substances present and operating conditions.

Each layer can be replaced separately. Start by checking the first-stage pad when airflow drops or the alarm sounds. Filter life depends on the material, operating time and loading. Odor reduction does not establish that air is safe.

WORKSTATION APPLICATIONS

Soldering, repair, nail dust.
Plus small laser projects.

01

Soldering & repair

Use source capture for PCB soldering and electronics repair. Position the hood near the smoke source while keeping room for hands and tools.

02

Nail dust

Place the hood near the filing area to collect dust as it is generated. Inspect the pre-filter regularly and arrange the hose around your workstation.

03

Small laser projects

MN01W also supports small laser engraving and cutting machines, such as 5W units. Share your material, enclosure and smoke load so we can confirm the capture and outdoor exhaust arrangement.

MN01W shares the soldering, electronics repair and nail-dust applications of MN01, with an additional option for small laser engraving and cutting. A 5W rating alone does not determine suitability: the material, smoke load and connections also matter. Larger machines or heavier smoke loads may require a larger extraction system.

CONTROLS & DAILY CARE

Adjust airflow from your working position.

01 / DISPLAY

S10–S100 settings

The digital display shows ten airflow levels. Select the setting using the front-panel buttons or remote control.

02 / REMOTE

Power & airflow control

Switch the unit on or off and adjust suction with the remote when the machine sits beside the bench.

03 / FILTER ALERT

Audible maintenance reminder

A beeping alert indicates saturated or clogged filters. Switch off and unplug before inspection, starting with the pre-filter. Replace loaded layers according to the manual.

PRODUCT DEMONSTRATION

See MN01W in operation.

SELECTION & SUPPORT

Questions about MN01W.

How is MN01W different from MN01?

MN01W adds a side exhaust connection for the outdoor exhaust hose. Choose it when your installation calls for routing residual odors outdoors. Compare the exact configuration and connections before ordering.

Is the outdoor hose required for every task?

The listed configuration can be used without the outdoor exhaust hose for normal soldering setups. The hose provides an additional routing option; assess material and ventilation requirements for each task.

What accessories are listed?

The Amazon description lists a 2 m outdoor exhaust hose, a flexible capture hose, round and rectangular hoods, remote control and 10 spare first-layer pre-filters. Confirm the final package, voltage and configuration in the selected offer or quotation.

Do all filters need replacing together?

No. The three layers are separately replaceable. Inspect the first-stage pad first, then assess the HEPA and activated-carbon layers according to their condition and the manual.

Can we order for distribution or private label?

Contact the factory with your target market, branding requirements and expected quantity. We will confirm the MN01W specification, customization options, warranty terms and quotation.

CHECK YOUR APPLICATION

Is MN01W right
for your workstation?

Tell us your process, material and required quantity.

Talk to Our Team ↗
WhatsApp ↗